How to Calibrate Your Eutech conductivity meter CON 700: A Step-by-Step Guide

If you own a Eutech Conductivity Meter CON 700, it is essential to calibrate it regularly to ensure accurate readings. Calibration is the process of adjusting the meter to match a known standard, such as a calibration solution. This ensures that the readings you get from the meter are reliable and accurate. In this article, we will provide you with a step-by-step guide on how to calibrate your Eutech Conductivity Meter CON 700.

alt-511
Before you begin the calibration process, make sure you have the necessary equipment on hand. You will need a calibration solution with a known conductivity value, as well as distilled water for rinsing the probe between calibration points. It is also a good idea to have a clean cloth or tissue to wipe the probe dry.

To start the calibration process, turn on the meter and allow it to warm up for a few minutes. Once the meter is ready, immerse the probe into the calibration solution. Make sure the probe is fully submerged and that there are no air bubbles trapped around it.

Next, press the “Cal” button on the meter to enter calibration mode. The meter will prompt you to select the calibration point. For the Eutech Conductivity Meter CON 700, there are typically two calibration points: one at low conductivity and one at high conductivity. Follow the on-screen instructions to select the appropriate calibration point.

Once you have selected the calibration point, the meter will display the current reading. Compare this reading to the known conductivity value of the calibration solution. If there is a discrepancy, use the calibration knob on the meter to adjust the reading until it matches the known value.

Product Model MFC-8800
Communication port The uplink slave channel Modbus RTU protocol RS485 port is connected with DTU and DCS
Downlink master channel RS485 port of Modbus RTU protocol is connected with data acquisition terminal
4~20mA\\u00a0output 1 channel two-wire type \\u00a0Maximum loop resistance 400\\u03a9
4~20mA\\u00a0Input \\u00a02 channel channel two-wire type\\uff08\\u00a0initiative feed\\uff09
DI\\u00a0Input \\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a0\\u00a02channels Photoelectric isolation logic switch
DO Output 3\\u00a0channels relay 1\\u00a0SPDT \\u00a0AC220V\\uff1b 3A(MAX)
\\uff08only for drive signal\\uff09 2\\u00a0SPST \\u00a0AC220V\\uff1b 3A(MAX)
1channel \\u00a0Photoelectric switch \\u00a0\\u00a0 Proportional pulse/frequency
\\u00a0Load capacity\\uff1a100mA/DC30V
\\u00a0Data acquisition Data acquisition collection\\uff0cwith 3\\u00a0channels DC24V sensor power supply \\u00a0
Display mode 3.5\\u201d\\uff08or 4\\u201d\\uff09colorful LCD\\u00a0touch screen
Power supply Wide power range \\uff1a\\uff0812-24\\uff09V
Consumption <5W
Environment requirements Environment temp\\uff1a\\uff085~45\\uff09\\u2103\\uff1b \\u00a0relative humidity\\uff1a\\u226490%\\u3002
Hole dimension \\uff0891\\u00d791\\uff09mm\\u00a0hole dimension\\uff1bpanel dimension\\uff08100*100\\uff09mm

After you have adjusted the reading to match the known value, press the “Enter” button to save the calibration point. Rinse the probe with distilled water to remove any residue from the calibration solution, and repeat the process for the second calibration point if necessary.

Once you have completed the calibration process for both points, the meter will display a confirmation message indicating that the calibration was successful. You can now use the meter to take accurate conductivity readings with confidence.

It is important to note that calibration should be done regularly to ensure the accuracy of your meter. Factors such as temperature, age of the probe, and frequency of use can all affect the performance of the meter and may require more frequent calibration.

In conclusion, calibrating your Eutech Conductivity Meter CON 700 is a simple process that can be done quickly and easily with the right equipment and know-how. By following the step-by-step guide outlined in this article, you can ensure that your meter provides accurate and reliable readings every time. Remember to calibrate your meter regularly to maintain its performance and accuracy.

Similar Posts