{"id":24101,"date":"2024-08-30T14:20:00","date_gmt":"2024-08-30T06:20:00","guid":{"rendered":"https:\/\/chimaytech.net\/?p=24101"},"modified":"2024-08-31T11:29:22","modified_gmt":"2024-08-31T03:29:22","slug":"hach-conductivity-meter","status":"publish","type":"post","link":"https:\/\/chimaytech.net\/tr\/hach-conductivity-meter\/","title":{"rendered":"hach iletkenlik \u00f6l\u00e7er"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/chimaytech.net\/tr\/hach-conductivity-meter\/#Hach_Iletkenlik_Olcer_Nasil_Kalibre_Edilir\" title=\"Hach \u0130letkenlik \u00d6l\u00e7er Nas\u0131l Kalibre Edilir\">Hach \u0130letkenlik \u00d6l\u00e7er Nas\u0131l Kalibre Edilir<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/chimaytech.net\/tr\/hach-conductivity-meter\/#Hach_Iletkenlik_Olceriniz_Icin_Duzenli_Bakimin_Onemi\" title=\"Hach \u0130letkenlik \u00d6l\u00e7eriniz \u0130\u00e7in D\u00fczenli Bak\u0131m\u0131n \u00d6nemi\">Hach \u0130letkenlik \u00d6l\u00e7eriniz \u0130\u00e7in D\u00fczenli Bak\u0131m\u0131n \u00d6nemi<\/a><\/li><\/ul><\/nav><\/div>\n<h1 id=\"how-to-calibrate-a-hach-conductivity-meter-wpaicgheading\"><span class=\"ez-toc-section\" id=\"Hach_Iletkenlik_Olcer_Nasil_Kalibre_Edilir\"><\/span>Hach \u0130letkenlik \u00d6l\u00e7er Nas\u0131l Kalibre Edilir<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\nHach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n kalibre edilmesi, do\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmler sa\u011flamada \u00f6nemli bir ad\u0131md\u0131r. \u0130letkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131 su ar\u0131tma, \u00e7evresel izleme ve ara\u015ft\u0131rma laboratuvarlar\u0131 dahil olmak \u00fczere \u00e7e\u015fitli end\u00fcstrilerde kullan\u0131lmaktad\u0131r. \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131n do\u011fru \u015fekilde kalibre edilmesi, hassas okumalar elde etmek ve cihaz\u0131n do\u011frulu\u011funu zaman i\u00e7inde korumak i\u00e7in \u00e7ok \u00f6nemlidir.<\/p>\n<p>Bir Hach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 kalibre etmek i\u00e7in birka\u00e7 temel \u00f6\u011feye ihtiyac\u0131n\u0131z olacakt\u0131r: kalibrasyon standart \u00e7\u00f6zeltisi, temiz bir beher veya kap ve iletkenlik metrenin kendisi. Kalibrasyon standard\u0131 \u00e7\u00f6zeltisinin, \u00f6l\u00e7ece\u011finiz numunelerin beklenen aral\u0131\u011f\u0131na yak\u0131n, bilinen bir iletkenlik de\u011ferine sahip olmas\u0131 gerekir. Hach, iletkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131yla kullan\u0131lmak \u00fczere \u00f6zel olarak tasarlanm\u0131\u015f bir dizi kalibrasyon standard\u0131 \u00e7\u00f6z\u00fcm\u00fc sunar.<\/p>\n<div style=\"width: 640px;\" class=\"wp-video\"><!--[if lt IE 9]><script>document.createElement('video');<\/script><![endif]-->\n<video class=\"wp-video-shortcode\" id=\"video-24101-1\" width=\"640\" height=\"360\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/ROC-8221-Factory-supply-Single-Stage-Double-Channels-RO-Controller.mp4?_=1\" \/><a href=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/ROC-8221-Factory-supply-Single-Stage-Double-Channels-RO-Controller.mp4\">http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/ROC-8221-Factory-supply-Single-Stage-Double-Channels-RO-Controller.mp4<\/a><\/video><\/div>\n<p>Kalibrasyon i\u015flemine ba\u015flamadan \u00f6nce iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n temiz oldu\u011fundan ve okumalar\u0131n do\u011frulu\u011funu etkileyebilecek her t\u00fcrl\u00fc kir veya kal\u0131nt\u0131dan ar\u0131nm\u0131\u015f oldu\u011fundan emin olmak \u00f6nemlidir. Probu deiyonize suyla iyice durulay\u0131n ve temiz, t\u00fcy b\u0131rakmayan bir bezle yava\u015f\u00e7a kurulay\u0131n. Probun \u00f6l\u00e7\u00fcm cihaz\u0131na g\u00fcvenli bir \u015fekilde tak\u0131ld\u0131\u011f\u0131ndan ve t\u00fcm ba\u011flant\u0131lar\u0131n s\u0131k\u0131 oldu\u011fundan emin olun.<\/p>\n<p>Cihaz temizlendi\u011finde ve kalibrasyona haz\u0131r oldu\u011funda, temiz bir beher veya kaba az miktarda kalibrasyon standart sol\u00fcsyonu d\u00f6k\u00fcn. \u0130letkenlik \u00f6l\u00e7erin sondas\u0131n\u0131 tamamen suya bat\u0131r\u0131ld\u0131\u011f\u0131ndan ve sondan\u0131n etraf\u0131nda hava kabarc\u0131\u011f\u0131 kalmad\u0131\u011f\u0131ndan emin olarak \u00e7\u00f6zeltiye yerle\u015ftirin. \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131n ekranda g\u00f6r\u00fcnt\u00fclenen iletkenlik de\u011ferini stabilize etmesine ve okumas\u0131na izin verin.<\/p>\n<p>Cihazdaki okumay\u0131 kalibrasyon standart \u00e7\u00f6zeltisinin bilinen iletkenlik de\u011feriyle kar\u015f\u0131la\u015ft\u0131r\u0131n. \u0130ki de\u011fer aras\u0131nda \u00f6nemli bir fark varsa \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n kalibrasyonunu ayarlaman\u0131z gerekecektir. \u00c7o\u011fu Hach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131, okumalar\u0131 bilinen standart de\u011ferle e\u015fle\u015fecek \u015fekilde kolayca ayarlaman\u0131za olanak tan\u0131yan yerle\u015fik bir kalibrasyon \u00f6zelli\u011fine sahiptir.<\/p>\n<p>Sayac\u0131n kalibrasyonunu ayarlamak i\u00e7in, kendi modelinize uygun kullan\u0131m k\u0131lavuzunda verilen talimatlar\u0131 izleyin. Bu, \u00f6l\u00e7\u00fcm cihaz\u0131nda bir kalibrasyon moduna girmeyi ve okumalar\u0131 bilinen standart de\u011ferle e\u015fle\u015fene kadar ayarlamak i\u00e7in d\u00fc\u011fmeleri veya kadranlar\u0131 kullanmay\u0131 i\u00e7erebilir. Kalibrasyon ayarland\u0131ktan sonra, \u00f6l\u00e7\u00fcmlerin do\u011fru oldu\u011fundan emin olmak i\u00e7in probu deiyonize suyla durulay\u0131n ve kalibrasyon i\u015flemini tekrarlay\u0131n.<\/p>\n<p>Hach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131 d\u00fczenli olarak, ideal olarak her kullan\u0131mdan \u00f6nce veya en az ayda bir kez kalibre etmeniz \u00f6nerilir. do\u011fru ve g\u00fcvenilir kalmas\u0131n\u0131 sa\u011flamak. D\u00fczenli kalibrasyona ek olarak, \u00f6mr\u00fcn\u00fc uzatmak ve tutarl\u0131 performans sa\u011flamak i\u00e7in iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n uygun \u015fekilde saklanmas\u0131 ve bak\u0131m\u0131 \u00f6nemlidir.<\/p>\n<p>Sonu\u00e7 olarak, Hach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n kalibre edilmesi, do\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmler elde etmede basit ama \u00f6nemli bir ad\u0131md\u0131r. Bu makalede \u00f6zetlenen ad\u0131mlar\u0131 takip ederek ve \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131 d\u00fczenli olarak kalibre ederek, cihaz\u0131n\u0131z\u0131n gelecek y\u0131llarda da hassas \u00f6l\u00e7\u00fcmler sa\u011flamaya devam etmesini sa\u011flayabilirsiniz.<\/p>\n<h1 id=\"the-importance-of-regular-maintenance-for-your-hach-conductivity-meter-wpaicgheading\"><span class=\"ez-toc-section\" id=\"Hach_Iletkenlik_Olceriniz_Icin_Duzenli_Bakimin_Onemi\"><\/span>Hach \u0130letkenlik \u00d6l\u00e7eriniz \u0130\u00e7in D\u00fczenli Bak\u0131m\u0131n \u00d6nemi<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\nHach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n do\u011frulu\u011funu ve g\u00fcvenilirli\u011fini sa\u011flamak i\u00e7in d\u00fczenli bak\u0131m \u015fartt\u0131r. \u0130letkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131, bir \u00e7\u00f6zeltinin iletkenli\u011fini \u00f6l\u00e7mek i\u00e7in su ar\u0131tma, ila\u00e7 ve yiyecek ve i\u00e7ecek \u00fcretimi dahil olmak \u00fczere \u00e7e\u015fitli end\u00fcstrilerde kullan\u0131l\u0131r. \u0130letkenlik, bir \u00e7\u00f6zeltinin elektrik ak\u0131m\u0131n\u0131 iletme yetene\u011finin bir \u00f6l\u00e7\u00fcs\u00fcd\u00fcr ve bu, \u00e7\u00f6zelti i\u00e7inde bulunan iyonlar\u0131n konsantrasyonundan etkilenir.<\/p>\n<p>Hach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n bak\u0131m\u0131n\u0131n en \u00f6nemli y\u00f6nlerinden biri, onu d\u00fczenli olarak kalibre etmektir. Kalibrasyon, \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n do\u011fru okumalar yapmas\u0131n\u0131 sa\u011flar ve do\u011frulu\u011funu sa\u011flamak i\u00e7in gerekli ayarlamalar\u0131 yapman\u0131za olanak tan\u0131r. Hach iletkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131 genellikle \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 kalibre etmek i\u00e7in kullan\u0131lan kalibrasyon \u00e7\u00f6z\u00fcmleriyle birlikte gelir. \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131n do\u011fru \u015fekilde kalibre edildi\u011finden emin olmak i\u00e7in \u00fcreticinin kalibrasyon talimatlar\u0131n\u0131 takip etmek \u00f6nemlidir.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/chimaytech.net\/wp-content\/uploads\/2023\/11\/FL-9900-High-Precision-Type-Runner-Flow-Controller-Spec.png\" alt=\"alt-8516\" class=\"wp-image-8516\" id=\"i8516\" \/><\/p>\n<p>Kalibrasyona ek olarak Hach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n temizlenmesi ve uygun \u015fekilde saklanmas\u0131 da \u00f6nemlidir. \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131n d\u00fczenli olarak temizlenmesi, elektrotlar \u00fczerinde okumalar\u0131n do\u011frulu\u011funu etkileyebilecek kirletici maddelerin birikmesini \u00f6nlemeye yard\u0131mc\u0131 olur. Elektrotlar\u0131 temizlemek i\u00e7in yumu\u015fak bir deterjan ve yumu\u015fak bir f\u0131r\u00e7a kullan\u0131lmas\u0131, zarar vermemeye dikkat edilmesi \u00f6nerilir. Sayac\u0131n uygun \u015fekilde saklanmas\u0131, hasardan korunmas\u0131 ve uzun \u00f6m\u00fcrl\u00fc olmas\u0131 a\u00e7\u0131s\u0131ndan da \u00f6nemlidir. \u00d6l\u00e7\u00fcm aletini do\u011frudan g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131ndan ve a\u015f\u0131r\u0131 s\u0131cakl\u0131klardan uzak, temiz, kuru bir yerde saklamak \u00f6mr\u00fcn\u00fcn uzamas\u0131na yard\u0131mc\u0131 olacakt\u0131r.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>DO-810\/1800 \u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen \u00d6l\u00e7er<\/td>\n<\/tr>\n<tr>\n<td>Aral\u0131k<\/td>\n<td>0-20,00 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Do\u011fruluk<\/td>\n<td>y\u00fczde 10,5 FS<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k. Komp.<\/td>\n<td>0-60\u2103<\/td>\n<\/tr>\n<tr>\n<td>Oper. S\u0131cakl\u0131k<\/td>\n<td>0\uff5e60\u2103<\/td>\n<\/tr>\n<tr>\n<td>Sens\u00f6r<\/td>\n<td>\u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen Sens\u00f6r\u00fc<\/td>\n<\/tr>\n<tr>\n<td>Ekran<\/td>\n<td>Segment kod i\u015flemi\/128*64 LCD Ekran(DO-1800)<\/td>\n<\/tr>\n<tr>\n<td>\u0130leti\u015fim<\/td>\n<td>\u0130ste\u011fe ba\u011fl\u0131 RS485<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u0131k\u0131\u015f<\/td>\n<td>4-20mA \u00e7\u0131k\u0131\u015f\u00a0 Y\u00fcksek\/Alt limitli \u00e7ift r\u00f6le kontrol\u00fc<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7<\/td>\n<td>AC 220V= y\u00fczde 110 50\/60Hz veya AC 110V\u0000\u00fczde110 50\/60Hz veya DC24V\/0,5A<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\u00c7al\u0131\u015fma Ortam\u0131<\/td>\n<td>Ortam s\u0131cakl\u0131\u011f\u0131:0\uff5e50\u2103<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011f\u0131l nem\u226485 y\u00fczde <\/td>\n<\/tr>\n<tr>\n<td>Boyutlar<\/td>\n<td>96\u00d796\u00d7100mm(Y\u00d7W\u00d7L)<\/td>\n<\/tr>\n<tr>\n<td>Delik Boyutu<\/td>\n<td>92\u00d792mm(Y\u00d7G)<\/td>\n<\/tr>\n<tr>\n<td>Kurulum Modu<\/td>\n<td>G\u00f6m\u00fcl\u00fc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nHach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n d\u00fczenli bak\u0131m\u0131 yaln\u0131zca do\u011frulu\u011funu sa\u011flamakla kalmaz, ayn\u0131 zamanda gelecekte maliyetli onar\u0131m veya de\u011fi\u015ftirmelerin \u00f6nlenmesine de yard\u0131mc\u0131 olur. \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n bak\u0131m\u0131n\u0131 do\u011fru \u015fekilde yapmaya zaman ay\u0131rarak \u00f6mr\u00fcn\u00fc uzatabilir ve do\u011fru iletkenlik \u00f6l\u00e7\u00fcmleri i\u00e7in ona g\u00fcvenmeye devam edebilirsiniz.<\/p>\n<p>Hach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n bak\u0131m\u0131n\u0131n bir di\u011fer \u00f6nemli y\u00f6n\u00fc, herhangi bir a\u015f\u0131nma veya hasar belirtisine kar\u015f\u0131 rutin kontroller yapmakt\u0131r. Elektrotlar\u0131n ve kablolar\u0131n herhangi bir korozyon, \u00e7atlak veya ba\u015fka hasar belirtisi a\u00e7\u0131s\u0131ndan incelenmesi, sorunlar\u0131n erkenden tespit edilmesine ve bunlar\u0131n okumalar\u0131n do\u011frulu\u011funu etkilemesinin \u00f6nlenmesine yard\u0131mc\u0131 olabilir. Herhangi bir hasar bulunursa, \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n daha fazla hasar g\u00f6rmesini \u00f6nlemek i\u00e7in derhal m\u00fcdahale edilmesi \u00f6nemlidir.<\/p>\n<p>Hach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n d\u00fczenli bak\u0131m\u0131, iletkenlik \u00f6l\u00e7\u00fcmlerinizin do\u011frulu\u011funu ve g\u00fcvenilirli\u011fini sa\u011flamak i\u00e7in \u00e7ok \u00f6nemlidir. \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131 kalibre ederek, temizleyerek ve uygun \u015fekilde saklayarak \u00f6mr\u00fcn\u00fc uzatabilir ve do\u011fru okumalar i\u00e7in ona g\u00fcvenmeye devam edebilirsiniz. Herhangi bir a\u015f\u0131nma veya hasar belirtisine kar\u015f\u0131 rutin kontrollerin yap\u0131lmas\u0131, herhangi bir sorunun erkenden tespit edilmesine ve \u00e7\u00f6z\u00fclmesine yard\u0131mc\u0131 olarak okumalar\u0131n do\u011frulu\u011funu etkilemesini \u00f6nleyebilir. Hach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n bak\u0131m\u0131n\u0131 do\u011fru \u015fekilde yapmak i\u00e7in zaman ay\u0131rman\u0131z, cihaz\u0131n gelecek y\u0131llarda do\u011fru ve g\u00fcvenilir iletkenlik \u00f6l\u00e7\u00fcmleri sa\u011flamaya devam etmesini sa\u011flamaya yard\u0131mc\u0131 olacakt\u0131r.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hach \u0130letkenlik \u00d6l\u00e7er Nas\u0131l Kalibre Edilir Hach iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n kalibre edilmesi, do\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmler sa\u011flamada \u00f6nemli bir ad\u0131md\u0131r. \u0130letkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131 su ar\u0131tma, \u00e7evresel izleme ve ara\u015ft\u0131rma laboratuvarlar\u0131 dahil olmak \u00fczere \u00e7e\u015fitli end\u00fcstrilerde kullan\u0131lmaktad\u0131r. \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131n do\u011fru \u015fekilde kalibre edilmesi, hassas okumalar elde etmek ve cihaz\u0131n do\u011frulu\u011funu zaman i\u00e7inde korumak i\u00e7in \u00e7ok \u00f6nemlidir&#8230;.<\/p>\n","protected":false},"author":1,"featured_media":1479,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"default","_kad_post_title":"default","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[202],"tags":[87076,203228,87081,87373],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"tr","enabled_languages":["en","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"ar":{"title":true,"content":true,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"id":{"title":true,"content":true,"excerpt":false},"hi":{"title":true,"content":true,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/posts\/24101"}],"collection":[{"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/comments?post=24101"}],"version-history":[{"count":16,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/posts\/24101\/revisions"}],"predecessor-version":[{"id":24234,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/posts\/24101\/revisions\/24234"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/media\/1479"}],"wp:attachment":[{"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/media?parent=24101"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/categories?post=24101"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/tags?post=24101"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}