{"id":20667,"date":"2024-08-01T13:35:58","date_gmt":"2024-08-01T05:35:58","guid":{"rendered":"https:\/\/chimaytech.net\/?p=20667"},"modified":"2024-08-01T18:11:19","modified_gmt":"2024-08-01T10:11:19","slug":"hach-sc200-conductivity-calibration","status":"publish","type":"post","link":"https:\/\/chimaytech.net\/tr\/hach-sc200-conductivity-calibration\/","title":{"rendered":"hach sc200 iletkenlik kalibrasyonu"},"content":{"rendered":"<h1 id=\"how-to-calibrate-the-hach-sc200-conductivity-meter-wpaicgheading\">Hach SC200 \u0130letkenlik \u00d6l\u00e7er Nas\u0131l Kalibre Edilir<\/h1>\n<p>\n\u0130letkenlik \u00f6l\u00e7erin kalibre edilmesi, su kalitesinin do\u011fru \u00f6l\u00e7\u00fcmlerinin sa\u011flanmas\u0131nda \u00f6nemli bir ad\u0131md\u0131r. Hach SC200 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131, \u00e7evresel izleme, at\u0131k su ar\u0131tma ve ara\u015ft\u0131rma da dahil olmak \u00fczere \u00e7e\u015fitli sekt\u00f6rlerdeki profesyoneller aras\u0131nda pop\u00fcler bir se\u00e7imdir. G\u00fcvenilir ve hassas okumalar elde etmek i\u00e7in SC200&#8217;\u00fcn do\u011fru kalibrasyonu \u00e7ok \u00f6nemlidir.<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/EC-8851-\u9ad8\u7cbe\u5ea6\u7535\u5bfc\u7387\u4eea2-1.png\" alt=\"alt-761\" class=\"wp-image-761\" id=\"i761\" \/><\/p>\n<p>\nHach SC200 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 kalibre etmek i\u00e7in birka\u00e7 temel \u00f6\u011feye ihtiyac\u0131n\u0131z olacakt\u0131r: kalibrasyon standard\u0131 sol\u00fcsyonu, temiz bir beher veya kap ve SC200 \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n kendisi. Kalibrasyon standard\u0131 \u00e7\u00f6zeltisinin, \u00f6l\u00e7ece\u011finiz numunelerin beklenen iletkenlik aral\u0131\u011f\u0131na yak\u0131n, bilinen bir iletkenlik de\u011ferine sahip olmas\u0131 gerekir. Do\u011frulu\u011fu sa\u011flamak i\u00e7in \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 her kalibre etti\u011finizde yeni bir kalibrasyon standard\u0131 \u00e7\u00f6z\u00fcm\u00fc kullanmak \u00f6nemlidir.<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"Brass Pressure Sensor For Havc Chimay\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/1jaH1uQP5kI?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>SC200 \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 a\u00e7arak ve birka\u00e7 dakika \u0131s\u0131nmas\u0131na izin vererek ba\u015flay\u0131n. Cihaz haz\u0131r oldu\u011funda, temiz bir behere az miktarda kalibrasyon standard\u0131 sol\u00fcsyonu d\u00f6k\u00fcn. Sol\u00fcsyonun \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n elektrotlar\u0131n\u0131 kaplad\u0131\u011f\u0131ndan emin olun. Elektrotlar\u0131 \u00e7\u00f6zeltiye yerle\u015ftirin ve okuman\u0131n stabil hale gelmesini bekleyin. Cihaz, kalibrasyon standart \u00e7\u00f6zeltisinin iletkenlik de\u011ferini g\u00f6stermelidir.<\/p>\n<p>G\u00f6r\u00fcnt\u00fclenen de\u011feri, kalibrasyon standart \u00e7\u00f6zeltisinin bilinen iletkenlik de\u011feriyle kar\u015f\u0131la\u015ft\u0131r\u0131n. \u0130ki de\u011fer aras\u0131nda \u00f6nemli bir fark varsa \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n kalibrasyonunu ayarlaman\u0131z gerekecektir. Hach SC200 de dahil olmak \u00fczere iletkenlik \u00f6l\u00e7\u00fcm cihazlar\u0131n\u0131n \u00e7o\u011fu, okumalar\u0131 kalibrasyon standart \u00e7\u00f6zeltisinin bilinen de\u011ferlerine uyacak \u015fekilde ayarlaman\u0131za olanak tan\u0131yan bir kalibrasyon \u00f6zelli\u011fine sahiptir.<\/p>\n<p>SC200 \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n kalibrasyonunu ayarlamak i\u00e7in kullan\u0131m k\u0131lavuzunda verilen talimatlar\u0131 izleyin. . Tipik olarak bu, \u00f6l\u00e7\u00fcm cihaz\u0131nda bir kalibrasyon moduna girmeyi ve okumalar\u0131 kalibrasyon standart \u00e7\u00f6z\u00fcm\u00fcn\u00fcn bilinen iletkenlik de\u011feriyle e\u015fle\u015fecek \u015fekilde ayarlamak i\u00e7in d\u00fc\u011fmeleri veya kadranlar\u0131 kullanmay\u0131 i\u00e7erir. Kalibrasyon tamamland\u0131ktan sonra elektrotlar\u0131 temiz suyla durulay\u0131n ve yumu\u015fak bir bezle kurulay\u0131n.<\/p>\n<p>Daha geni\u015f bir iletkenlik de\u011feri aral\u0131\u011f\u0131nda do\u011fruluk sa\u011flamak i\u00e7in Hach SC200 iletkenlik \u00f6l\u00e7erin iki noktal\u0131 kalibrasyonunun yap\u0131lmas\u0131 \u00f6nerilir. Bunu yapmak i\u00e7in farkl\u0131 iletkenlik de\u011ferine sahip ikinci bir kalibrasyon standard\u0131 \u00e7\u00f6zeltisi kullanarak kalibrasyon i\u015flemini tekrarlay\u0131n. Kirlenmeyi \u00f6nlemek i\u00e7in kalibrasyonlar aras\u0131nda elektrotlar\u0131 iyice durulad\u0131\u011f\u0131n\u0131zdan emin olun.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>CL-810\/9500 Art\u0131k Klor Kontrol Cihaz\u0131<\/td>\n<\/tr>\n<tr>\n<td>Aral\u0131k<\/td>\n<td>FAC\/HOCL:0-10 mg\/L, ATC TEMP:0-50\u2103<\/td>\n<\/tr>\n<tr>\n<td>Do\u011fruluk<\/td>\n<td>FAC\/HOCL:0,1 mg\/L, ATC TEMP:0,1\u2103<\/td>\n<\/tr>\n<tr>\n<td>Oper. S\u0131cakl\u0131k<\/td>\n<td>0\uff5e50\u2103<\/td>\n<\/tr>\n<tr>\n<td>Sens\u00f6r<\/td>\n<td>Sabit Bas\u0131n\u00e7l\u0131 Art\u0131k Klor Sens\u00f6r\u00fc<\/td>\n<\/tr>\n<tr>\n<td>Su Ge\u00e7irmezlik Oran\u0131<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>\u0130leti\u015fim<\/td>\n<td>\u0130ste\u011fe ba\u011fl\u0131 RS485<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u0131k\u0131\u015f<\/td>\n<td>4-20mA \u00e7\u0131k\u0131\u015f; Y\u00fcksek\/Alt limitli \u00e7ift r\u00f6le kontrol\u00fc<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">G\u00fc\u00e7<\/td>\n<td>CL-810:AC 220V<br \/>\n\u0000\u00fczde110 50\/60Hz veya AC 110V<br \/>\n\u0000\u00fczde110 50\/60Hz veya DC24V\/0,5A<\/td>\n<\/tr>\n<tr>\n<td>CL-9500:AC 85V-265V\u0000\u00fczde 110 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\u00c7al\u0131\u015fma Ortam\u0131<\/td>\n<td>Ortam s\u0131cakl\u0131\u011f\u0131:0\uff5e50\u2103;<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011f\u0131l nem\u226485 y\u00fczde <\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Boyutlar<\/td>\n<td>CL-810:96\u00d796\u00d7100mm(Y\u00d7W\u00d7L)<\/td>\n<\/tr>\n<tr>\n<td>CL-9500:96\u00d796\u00d7132mm(Y\u00d7W\u00d7L)<\/td>\n<\/tr>\n<tr>\n<td>Delik Boyutu<\/td>\n<td>92\u00d792mm(Y\u00d7G)<\/td>\n<\/tr>\n<tr>\n<td>Kurulum Modu<\/td>\n<td>G\u00f6m\u00fcl\u00fc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nSC200 \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131 kalibre ettikten sonra do\u011frulu\u011funu korumak i\u00e7in uygun \u015fekilde saklamak \u00f6nemlidir. \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131 do\u011frudan g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131ndan ve a\u015f\u0131r\u0131 s\u0131cakl\u0131klardan uzak, temiz ve kuru bir yerde saklay\u0131n. Elektrotlarda herhangi bir hasar veya a\u015f\u0131nma belirtisi olup olmad\u0131\u011f\u0131n\u0131 d\u00fczenli olarak kontrol edin ve gerekti\u011finde de\u011fi\u015ftirin.<\/p>\n<p>Sonu\u00e7 olarak, Hjson SC200 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n kalibre edilmesi, su kalitesinin do\u011fru ve g\u00fcvenilir \u00f6l\u00e7\u00fcmlerini elde etmek i\u00e7in gerekli olan basit bir i\u015flemdir. Yukar\u0131da \u00f6zetlenen ad\u0131mlar\u0131 takip ederek ve d\u00fczenli kalibrasyonlar ger\u00e7ekle\u015ftirerek SC200 \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n \u00f6zel uygulaman\u0131z i\u00e7in hassas okumalar yapmas\u0131n\u0131 sa\u011flayabilirsiniz. Daima yeni kalibrasyon standart sol\u00fcsyonlar\u0131 kullanmay\u0131 ve kalibrasyon ve bak\u0131m i\u00e7in \u00fcreticinin talimatlar\u0131n\u0131 takip etmeyi unutmay\u0131n.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hach SC200 \u0130letkenlik \u00d6l\u00e7er Nas\u0131l Kalibre Edilir \u0130letkenlik \u00f6l\u00e7erin kalibre edilmesi, su kalitesinin do\u011fru \u00f6l\u00e7\u00fcmlerinin sa\u011flanmas\u0131nda \u00f6nemli bir ad\u0131md\u0131r. Hach SC200 iletkenlik \u00f6l\u00e7\u00fcm cihaz\u0131, \u00e7evresel izleme, at\u0131k su ar\u0131tma ve ara\u015ft\u0131rma da dahil olmak \u00fczere \u00e7e\u015fitli sekt\u00f6rlerdeki profesyoneller aras\u0131nda pop\u00fcler bir se\u00e7imdir. G\u00fcvenilir ve hassas okumalar elde etmek i\u00e7in SC200&#8217;\u00fcn do\u011fru kalibrasyonu \u00e7ok \u00f6nemlidir. Hach&#8230;<\/p>\n","protected":false},"author":1,"featured_media":19712,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"default","_kad_post_title":"default","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[202],"tags":[87076,203228,87124],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"tr","enabled_languages":["en","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"ar":{"title":true,"content":true,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"id":{"title":true,"content":true,"excerpt":false},"hi":{"title":true,"content":true,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/posts\/20667"}],"collection":[{"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/comments?post=20667"}],"version-history":[{"count":16,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/posts\/20667\/revisions"}],"predecessor-version":[{"id":20905,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/posts\/20667\/revisions\/20905"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/media\/19712"}],"wp:attachment":[{"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/media?parent=20667"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/categories?post=20667"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chimaytech.net\/tr\/wp-json\/wp\/v2\/tags?post=20667"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}