Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.
-


GL-2 Series of economical control valve is the same as the corresponding GL-1 in function and principle. it use “One dynamic & two static” three layer ceramic valve core technology, It adopts four key controller operation setting method, needless rotation station identification when power on every time.The inlet and outlet water is set on the side of the valve body.Small size, simple structure, no wear and tear, permanent life.It can be widely used in the purification of industrial and civil.
-

![[CL-9500] Water Quality Test Residual Chlorine Controller1 CL-9500 Water Quality Test Residual Chlorine Controller](https://chimaytech.net/wp-content/uploads/2023/11/CL-9500-Water-Quality-Test-Residual-Chlorine-Controller1-300x300.png)
CL-9500 residual chlorine controller is a new controller. This meter has a high degree of intelligence and flexibility. It can measure Residual chlorine value and temperature at the same time. It is widely used in urban sewage treatment plants, water supply and other industries and can continuously measure the Residual chlorine value of solution.
-


ROC-8221 is a combined control instrument of a single-stage reverse osmosis controller and double-channel on-line conductivity instrument.
-


Flexible 7 or 12 day time clock or meter initiated regeneration
Fully adjustable, 5-cycle control delivers upflow back wash, downflow brining, slow rinse, rapid rinse and down flow service
Designed for single tank or multi-tank systems, alternating or interlocking
Continuous flow rate of 250 GPM
-


Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.
-


Applicable to all kinds of small and medium-sized single-stage, double-stage reverse osmosis control system. With simple operation, complete measurement and configuration, highly integrated system
-


For complex industrial processes, sewage treatment, water reuse, environmental monitoring, industrial field control, chemical process, thermal detection and discrete control, data transmission control and remote data transmission.
-


Fluorescence quenching principle, no need for internal filling, no oxygen consumption, and easy maintenance;
The service life of the fluorescent membrane cap is more than one year (under ideal conditions);
Original altitude, atmospheric oxygen partial pressure, temperature compensation, to improve the authenticity of the data;