Factors Influencing the Price of Reverse Osmosis Analyzers in the Philippines
Reverse osmosis analyzers are essential tools in the field of water treatment and purification. They play a crucial role in ensuring water quality by measuring various parameters such as total dissolved solids (TDS), pH levels, and conductivity. In the Philippines, the price of reverse osmosis analyzers can vary significantly due to several factors that influence the pricing of these instruments.
ROS-8600 RO Program Control HMI Platform | ||
Model | ROS-8600 Single Stage | ROS-8600 Double Stage |
Measuring range | Source water0~2000uS/cm | Source water0~2000uS/cm |
First level effluent 0~200uS/cm | First level effluent 0~200uS/cm | |
secondary effluent 0~20uS/cm | secondary effluent 0~20uS/cm | |
Pressure sensor(optional) | Membrane pre/post pressure | Primary/ secondary membrane front/rear pressure |
ph sensor(optional) | —- | 0~14.00pH |
Signal collection | 1.Raw water low pressure | 1.Raw water low pressure |
2.Primary booster pump inlet low pressure | 2.Primary booster pump inlet low pressure | |
3.Primary booster pump outlet high pressure | 3.Primary booster pump outlet high pressure | |
4.High liquid level of Level 1 tank | 4.High liquid level of Level 1 tank | |
5.Low liquid level of Level 1 tank | 5.Low liquid level of Level 1 tank | |
6.Preprocessing signal | 6.2nd booster pump outlet high pressure | |
7.Input standby ports x2 | 7.High liquid level of Level 2 tank | |
8.Low liquid level of Level 2 tank | ||
9.Preprocessing signal | ||
10.Input standby ports x2 | ||
Output control | 1.Water inlet valve | 1.Water inlet valve |
2.Source water pump | 2.Source water pump | |
3.Primary booster pump | 3.Primary booster pump | |
4.Primary flush valve | 4.Primary flush valve | |
5.Primary dosing pump | 5.Primary dosing pump | |
6.Primary water over standard discharge valve | 6.Primary water over standard discharge valve | |
7.Alarm output node | 7.Secondary booster pump | |
8.Manual standby pump | 8.Secondary flush valve | |
9.Secondary dosing pump | 9.Secondary dosing pump | |
Output standby port x2 | 10.Secondary water over standard discharge valve | |
11.Alarm output node | ||
12.Manual standby pump | ||
Output standby port x2 | ||
The main function | 1.Correction of electrode constant | 1.Correction of electrode constant |
2.Overrun alarm setting | 2.Overrun alarm setting | |
3.All working mode time can be set | 3.All working mode time can be set | |
4.High and low pressure flushing mode setting | 4.High and low pressure flushing mode setting | |
5.The low pressure pump is opened when preprocessing | 5.The low pressure pump is opened when preprocessing | |
6.Manual/automatic can be chosen when boot up | 6.Manual/automatic can be chosen when boot up | |
7.Manual debugging mode | 7.Manual debugging mode | |
8.Alarm if communication interruption | 8.Alarm if communication interruption | |
9. Urging payment settings | 9. Urging payment settings | |
10. Company name,website can be customized | 10. Company name,website can be customized | |
Power supply | DC24V±10% | DC24V±10% |
Expansion interface | 1.Reserved relay output | 1.Reserved relay output |
2.RS485 communication | 2.RS485 communication | |
3.Reserved IO port, analog module | 3.Reserved IO port, analog module | |
4.Mobile/computer/touch screen synchronous display | 4.Mobile/computer/touch screen synchronous display | |
Relative humidity | ≦85% | ≤85% |
Environment temperature | 0~50℃ | 0~50℃ |
Touch screen size | 163x226x80mm (H x W x D) | 163x226x80mm (H x W x D) |
Hole Size | 7 inch:215*152mm(wide*high) | 215*152mm(wide*high) |
Controller size | 180*99(long*wide) | 180*99(long*wide) |
Transmitter size | 92*125(long*wide) | 92*125(long*wide) |
Installation method | Touch screen:panel embedded; Controller: plane fixed | Touch screen:panel embedded; Controller: plane fixed |
One of the primary factors that influence the price of reverse osmosis analyzers in the Philippines is the brand and manufacturer. Different brands offer a wide range of features, accuracy, and reliability, which can significantly impact the price of the analyzer. Established and reputable brands often command higher prices due to their quality, reliability, and advanced technology. On the other hand, lesser-known or generic brands may offer similar functionalities at a lower price point.
Model | pH/ORP-8851/9900 pH/orp meter |
Range | 0-14 pH; -2000 – +2000mV |
Accuracy | ±0.1pH; ±2mV |
Temp. Comp. | Automatic temperature compensation |
Oper. Temp. | Normal 0~60℃; High temp 0~100℃ |
Sensor | pH double/triple sensor; ORP sensor |
Display | Big Screen LCD Screen |
Communication | 4-20mA output/RS485 |
Output | High/Low limit dual relay control |
Power | DC24V/0.5A or AC85-265V±10% 50/60Hz |
Working Environment | Ambient temperature:0~50℃ |
Relative humidity≤85% | |
Dimensions | 96×96×72mm(H×W×L) |
Hole Size | 92×92mm(H×W) |
Installation Mode | Embedded |
The type and complexity of the reverse osmosis analyzer also play a significant role in determining its price. Some analyzers are designed to measure a single parameter, such as TDS or pH, while others are equipped to measure multiple parameters simultaneously. Analyzers with advanced features such as digital displays, data logging capabilities, and automated calibration tend to be priced higher than basic models. Additionally, the complexity of the analysis, such as the range of parameters measured and the accuracy of the measurements, can also impact the price of the analyzer.
The quality and durability of the materials used in the construction of the reverse osmosis analyzer can also influence its price. Analyzers built with high-quality, corrosion-resistant materials are likely to have a higher price tag due to their durability and long-term reliability. These materials ensure that the analyzer can withstand the harsh conditions often encountered in water treatment facilities, making them a preferred choice despite their higher cost.
Another factor that affects the price of reverse osmosis analyzers in the Philippines is the after-sales support and warranty provided by the manufacturer or distributor. Analyzers that come with comprehensive warranties, technical support, and readily available spare parts may have a higher initial price but offer long-term value and peace of mind to the buyer. On the other hand, cheaper analyzers may lack robust after-sales support, making them less attractive in the long run.
Furthermore, market demand and competition also play a role in determining the price of reverse osmosis analyzers in the Philippines. In a competitive market, manufacturers and distributors may adjust their pricing strategies to gain a competitive edge, resulting in fluctuations in the prices of these instruments.
In conclusion, the price of reverse osmosis analyzers in the Philippines is influenced by a variety of factors, including the brand, type and complexity, quality of materials, after-sales support, and market dynamics. Understanding these factors is crucial for making