ROS-360 Water Treatment RO Program Control System
Single stage RO controller used for conductivity monitoring and process program control .


Single stage RO controller used for conductivity monitoring and process program control .


Incorporates 2 time-tested, hydraulically-balanced pistons to independently pilot service flow and regeneration
For use with single or multiple tank systems
Backwashes softener tanks up to 36″ diameter
Continuous flow rate of 106 GPM


Easily-adjustable, 5-cycle, downflow-brining control
Rugged, long-life construction features a lead-free brass valve body
Uses conditioned water for regeneration


Free Chlorine (DPD) online automatic analyzer is mainly used for real-time monitoring of water plants, secondary water supply of pipe network, medical wastewater, kidney dialysis medical water, food and beverage water, swimming pools, circulating cooling water, enterprise discharge wastewater and other occasions.


Salt and water savings by using 100% capacity of the tank in service before switching to the second tank
Regenerates immediately when needed for continuous soft water
Corrosion-free fiber-reinforced polymer valve body


Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.


Fluorescence quenching principle, no need for internal filling, no oxygen consumption, and easy maintenance;
The service life of the fluorescent membrane cap is more than one year (under ideal conditions);
Original altitude, atmospheric oxygen partial pressure, temperature compensation, to improve the authenticity of the data;


CIT-8800 Inductive Conductivity / Concentration Online Controller is a new developed conductivity/Concentration/TDS/Temperature integration controller,with No electrode inductive Conductivity Sensor.


Meter and time dual mode, the meter mode, its inflow meter achieved all station can be set according to the water volume demanded , as long as set by the swap of tank volume (L) backwash water and wash water, set cycle running water volume(ton), according to the set value for each station after descending to the switch when the “0”, discontinued or no water stop decreasing and maintain. This series of products have beautiful appearance, high material precision of valve body parts, good strength and high temperature resistance, and the main valve body is connected with metal inserts with good maintainability.