{"id":20097,"date":"2024-06-13T14:38:56","date_gmt":"2024-06-13T06:38:56","guid":{"rendered":"https:\/\/chimaytech.net\/?p=20097"},"modified":"2024-06-14T14:34:20","modified_gmt":"2024-06-14T06:34:20","slug":"procedure-for-determination-of-ph-using-ph-meter","status":"publish","type":"post","link":"https:\/\/chimaytech.net\/fr\/procedure-for-determination-of-ph-using-ph-meter\/","title":{"rendered":"proc\u00e9dure de d\u00e9termination du pH \u00e0 l&#039;aide d&#039;un ph-m\u00e8tre"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/chimaytech.net\/fr\/procedure-for-determination-of-ph-using-ph-meter\/#Procedure_operatoire_standard_pour_l%E2%80%99etalonnage_d%E2%80%99un_pH-metre\" title=\"Proc\u00e9dure op\u00e9ratoire standard pour l&#8217;\u00e9talonnage d&#8217;un pH-m\u00e8tre\">Proc\u00e9dure op\u00e9ratoire standard pour l&#8217;\u00e9talonnage d&#8217;un pH-m\u00e8tre<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/chimaytech.net\/fr\/procedure-for-determination-of-ph-using-ph-meter\/#Guide_etape_par_etape_pour_mesurer_le_pH_a_l%E2%80%99aide_d%E2%80%99un_pH-metre\" title=\"Guide \u00e9tape par \u00e9tape pour mesurer le pH \u00e0 l&#8217;aide d&#8217;un pH-m\u00e8tre\">Guide \u00e9tape par \u00e9tape pour mesurer le pH \u00e0 l&#8217;aide d&#8217;un pH-m\u00e8tre<\/a><\/li><\/ul><\/nav><\/div>\n<h1 id=\"standard-operating-procedure-for-calibrating-a-ph-meter-wpaicgheading\"><span class=\"ez-toc-section\" id=\"Procedure_operatoire_standard_pour_l%E2%80%99etalonnage_d%E2%80%99un_pH-metre\"><\/span>Proc\u00e9dure op\u00e9ratoire standard pour l&#8217;\u00e9talonnage d&#8217;un pH-m\u00e8tre<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\nUn pH-m\u00e8tre est un outil crucial dans de nombreuses applications scientifiques et industrielles, car il permet de mesurer avec pr\u00e9cision l&#8217;acidit\u00e9 ou l&#8217;alcalinit\u00e9 d&#8217;une solution. Pour garantir la fiabilit\u00e9 des mesures de pH, il est indispensable de calibrer r\u00e9guli\u00e8rement le pH-m\u00e8tre. Dans cet article, nous pr\u00e9senterons la proc\u00e9dure op\u00e9ratoire standard pour l&#8217;\u00e9talonnage d&#8217;un pH-m\u00e8tre \u00e0 l&#8217;aide de solutions tampons.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Num\u00e9ro de mod\u00e8le<\/td>\n<td colspan=\"4\">Sp\u00e9cifications du contr\u00f4leur en ligne de r\u00e9sistivit\u00e9 et de conductivit\u00e9 CCT-8301A<\/td>\n<\/tr>\n<tr>\n<td>\\\u3000<\/td>\n<td>Conductivit\u00e9<\/td>\n<td>R\u00e9sistivit\u00e9<\/td>\n<td>TDS<\/td>\n<td>Temp.<\/td>\n<\/tr>\n<tr>\n<td>Plage de mesure<\/td>\n<td>0,1\\\u03bcS\/cm\\\uff5e40,0mS\/cm<\/td>\n<td>50K\\\u03a9\\\u00b7cm\\\uff5e18.25M\\\u03a9\\\u00b7cm<\/td>\n<td>0,25 ppm\\\uff5e20ppt<\/td>\n<td>(0\\\uff5e100)\\\u2103<\/td>\n<\/tr>\n<tr>\n<td>R\u00e9solution<\/td>\n<td>0,01\\\u03bcS\/cm<\/td>\n<td>0,01M\\\u03a9\\\u00b7cm<\/td>\n<td>0,01 ppm<\/td>\n<td>0.1\\\u2103<\/td>\n<\/tr>\n<tr>\n<td>Pr\u00e9cision<\/td>\n<td>1.5niveau<\/td>\n<td>niveau 2.0<\/td>\n<td>1.5niveau<\/td>\n<td>\\\u00b10.5\\\u2103<\/td>\n<\/tr>\n<tr>\n<td>Compensation Temp.<\/td>\n<td colspan=\"4\">Pt1000<\/td>\n<\/tr>\n<tr>\n<td>Environnement de travail<\/td>\n<td colspan=\"4\">Temp.\\\u00a0(0\\\uff5e50)\\\u2103; \\\u00a0humidit\u00e9 relative \\\u226485 pour cent HR<\/td>\n<\/tr>\n<tr>\n<td>Sortie analogique<\/td>\n<td colspan=\"4\">Double canal (4\\\uff5e20)mA\\\uff0cInstrument\/Transmetteur pour s\u00e9lection<\/td>\n<\/tr>\n<tr>\n<td>Sortie de contr\u00f4le<\/td>\n<td colspan=\"4\">Relais \u00e0 semi-conducteur photo\u00e9lectronique \u00e0 trois canaux, capacit\u00e9 de charge\u00a0: AC\/DC 30\u00a0V\\\uff0c50mA(max)<\/td>\n<\/tr>\n<tr>\n<td>Alimentation<\/td>\n<td colspan=\"4\">DC 24V\\\u00b115 pour cent <\/td>\n<\/tr>\n<tr>\n<td>Consommation<\/td>\n<td colspan=\"4\">\\\u22644W<\/td>\n<\/tr>\n<tr>\n<td>Niveau de protection<\/td>\n<td colspan=\"4\">IP65\\\uff08avec le cache arri\u00e8re\\\uff09<\/td>\n<\/tr>\n<tr>\n<td>Installation<\/td>\n<td colspan=\"4\">Panneau mont\u00e9<\/td>\n<\/tr>\n<tr>\n<td>Dimension<\/td>\n<td colspan=\"4\">96mm\\\u00d796mm\\\u00d794mm (H\\\u00d7W\\\u00d7D)<\/td>\n<\/tr>\n<tr>\n<td>Taille du trou<\/td>\n<td colspan=\"4\">91mm\\\u00d791mm(H\\\u00d7W)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nAvant de commencer le processus d&#8217;\u00e9talonnage, il est important de rassembler tout le mat\u00e9riel n\u00e9cessaire. Cela comprend le pH-m\u00e8tre, un ensemble de solutions tampons avec des valeurs de pH connues (g\u00e9n\u00e9ralement pH 4, 7 et 10), de l&#8217;eau distill\u00e9e et un b\u00e9cher ou un r\u00e9cipient propre pour rincer l&#8217;\u00e9lectrode entre les mesures.<\/p>\n<p>Pour d\u00e9marrer le processus d&#8217;\u00e9talonnage, tout d\u2019abord, assurez-vous que le pH-m\u00e8tre est propre et exempt de tout d\u00e9bris ou r\u00e9sidu. Rincez l&#8217;\u00e9lectrode avec de l&#8217;eau distill\u00e9e et s\u00e9chez-la d\u00e9licatement avec un chiffon propre. Ensuite, allumez le pH-m\u00e8tre et laissez-le chauffer pendant quelques minutes pour garantir des lectures pr\u00e9cises.<\/p>\n<p>Une fois le pH-m\u00e8tre pr\u00eat, plongez l&#8217;\u00e9lectrode dans la solution tampon pH 7. Laissez la lecture se stabiliser, ce qui peut prendre quelques instants. Une fois la lecture stabilis\u00e9e, ajustez le pH-m\u00e8tre pour qu&#8217;il corresponde \u00e0 la valeur pH connue de la solution tampon. Cela peut g\u00e9n\u00e9ralement \u00eatre fait en tournant un cadran ou en appuyant sur un bouton du pH-m\u00e8tre.<\/p>\n<p>Apr\u00e8s avoir calibr\u00e9 le pH-m\u00e8tre avec la solution tampon pH 7, rincez l&#8217;\u00e9lectrode avec de l&#8217;eau distill\u00e9e et r\u00e9p\u00e9tez le processus avec le tampon pH 4 et pH 10. solutions. Il est important d&#8217;\u00e9talonner le pH-m\u00e8tre avec au moins deux solutions tampons pour garantir la pr\u00e9cision sur une plage de valeurs de pH.<\/p>\n<p>Une fois le pH-m\u00e8tre calibr\u00e9 avec les solutions tampons, il est important de v\u00e9rifier la pente de l&#8217;\u00e9lectrode. Cela peut \u00eatre fait en mesurant le pH d&#8217;une solution tampon avec une valeur de pH connue et en la comparant \u00e0 la valeur attendue. Si le pH mesur\u00e9 s&#8217;\u00e9carte consid\u00e9rablement de la valeur attendue, l&#8217;\u00e9lectrode devra peut-\u00eatre \u00eatre remplac\u00e9e ou recalibr\u00e9e.<\/p>\n<p>En plus d&#8217;un \u00e9talonnage r\u00e9gulier, il est important de stocker et d&#8217;entretenir correctement le pH-m\u00e8tre pour garantir des mesures pr\u00e9cises. Rangez le pH-m\u00e8tre dans un endroit propre et sec lorsqu&#8217;il n&#8217;est pas utilis\u00e9 et rincez toujours l&#8217;\u00e9lectrode avec de l&#8217;eau distill\u00e9e apr\u00e8s chaque utilisation pour \u00e9viter toute contamination.<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"ro uv tds controller water purifier\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/1YB3-6QwTvI?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>En conclusion, l\u2019\u00e9talonnage d\u2019un pH-m\u00e8tre est une \u00e9tape cruciale pour garantir des mesures pr\u00e9cises du pH. En suivant la proc\u00e9dure op\u00e9rationnelle standard d\u00e9crite dans cet article, vous pouvez calibrer votre pH-m\u00e8tre en toute confiance et avoir confiance dans l&#8217;exactitude de vos r\u00e9sultats. N&#8217;oubliez pas de calibrer le pH-m\u00e8tre avec plusieurs solutions tampons, de v\u00e9rifier la pente de l&#8217;\u00e9lectrode et d&#8217;entretenir correctement le pH-m\u00e8tre pour des performances optimales.<\/p>\n<h1 id=\"step-by-step-guide-for-measuring-ph-using-a-ph-meter-wpaicgheading\"><span class=\"ez-toc-section\" id=\"Guide_etape_par_etape_pour_mesurer_le_pH_a_l%E2%80%99aide_d%E2%80%99un_pH-metre\"><\/span>Guide \u00e9tape par \u00e9tape pour mesurer le pH \u00e0 l&#8217;aide d&#8217;un pH-m\u00e8tre<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\nLa mesure du pH est une t\u00e2che essentielle dans divers domaines tels que la chimie, la biologie, les sciences de l&#8217;environnement et l&#8217;agriculture. Le pH est une mesure de l&#8217;acidit\u00e9 ou de l&#8217;alcalinit\u00e9 d&#8217;une solution, avec un pH de 7 consid\u00e9r\u00e9 comme neutre, inf\u00e9rieur \u00e0 7 acide et sup\u00e9rieur \u00e0 7 alcalin. L&#8217;une des m\u00e9thodes les plus courantes pour mesurer le pH consiste \u00e0 utiliser un pH-m\u00e8tre, un appareil qui mesure la concentration en ions hydrog\u00e8ne dans une solution. Dans cet article, nous fournirons un guide \u00e9tape par \u00e9tape sur la fa\u00e7on de mesurer le pH \u00e0 l&#8217;aide d&#8217;un pH-m\u00e8tre.<\/p>\n<p>Avant de commencer la mesure du pH, il est crucial de calibrer le pH-m\u00e8tre. L&#8217;\u00e9talonnage garantit l&#8217;exactitude des mesures et doit \u00eatre effectu\u00e9 avant chaque utilisation. Pour calibrer le pH-m\u00e8tre, vous aurez besoin de tampons d&#8217;\u00e9talonnage de valeurs de pH connues, g\u00e9n\u00e9ralement pH 4,01, pH 7,00 et pH 10,01. Commencez par rincer l\u2019\u00e9lectrode avec de l\u2019eau distill\u00e9e puis plongez-la dans la solution tampon pH 7,00. Laissez la lecture se stabiliser et ajustez l\u2019appareil \u00e0 la valeur de pH correcte \u00e0 l\u2019aide des contr\u00f4les d\u2019\u00e9talonnage. R\u00e9p\u00e9tez ce processus avec les autres tampons d&#8217;\u00e9talonnage.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Mod\u00e8le de produit<\/td>\n<td colspan=\"2\">MFC-8800<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Port de communication<\/td>\n<td colspan=\"2\">Le port RS485 du protocole Modbus RTU du canal esclave de liaison montante est connect\u00e9 au DTU et au DCS<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Le port RS485 du canal ma\u00eetre de liaison descendante du protocole Modbus RTU est connect\u00e9 au terminal d&#8217;acquisition de donn\u00e9es<\/td>\n<\/tr>\n<tr>\n<td>4~20mA\\\u00a0sortie<\/td>\n<td colspan=\"2\">Type \u00e0 deux fils \u00e0 1 canal \\\u00a0R\u00e9sistance de boucle maximale 400\\\u03a9<\/td>\n<\/tr>\n<tr>\n<td>4~20mA\\\u00a0Entr\u00e9e<\/td>\n<td colspan=\"2\">\\\u00a02 canal canal type \u00e0 deux fils\\\uff08\\\u00a0alimentation d&#8217;initiative\\\uff09<\/td>\n<\/tr>\n<tr>\n<td>DI\\\u00a0Entr\u00e9e<\/td>\n<td colspan=\"2\">\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\ \u00a02canaux Commutateur logique d&#8217;isolation photo\u00e9lectrique<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Sortie DO<\/td>\n<td>Relais 3\\\u00a0canaux<\/td>\n<td>1\\\u00a0SPDT \\\u00a0AC220V\\\uff1b 3A(MAX)<\/td>\n<\/tr>\n<tr>\n<td>\\\uff08uniquement pour le signal d&#8217;entra\u00eenement\\\uff09<\/td>\n<td>2\\\u00a0SPST \\\u00a0AC220V\\\uff1b 3A(MAX)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">1 canal \\\u00a0Interrupteur photo\u00e9lectrique \\\u00a0\\\u00a0<\/td>\n<td>Impulsion\/fr\u00e9quence proportionnelle<\/td>\n<\/tr>\n<tr>\n<td>\\\u00a0Capacit\u00e9 de charge\\\uff1a100mA\/DC30V<\/td>\n<\/tr>\n<tr>\n<td>\\\u00a0Acquisition de donn\u00e9es<\/td>\n<td colspan=\"2\">Collecte d&#8217;acquisition de donn\u00e9es\\\uff0cavec 3\\\u00a0canaux DC24V alimentation du capteur \\\u00a0<\/td>\n<\/tr>\n<tr>\n<td>Mode d&#8217;affichage<\/td>\n<td colspan=\"2\">\u00c9cran tactile LCD color\u00e9 3,5\\\uff08ou 4\\\u201d\uff09<\/td>\n<\/tr>\n<tr>\n<td>Alimentation<\/td>\n<td colspan=\"2\">Large plage de puissance \\\uff1a\\\uff0812-24\\\uff09V<\/td>\n<\/tr>\n<tr>\n<td>Consommation<\/td>\n<td colspan=\"2\"><5W<\/td>\n<\/tr>\n<tr>\n<td>Exigences environnementales<\/td>\n<td colspan=\"2\">Temp\u00e9rature de l&#8217;environnement\\\uff1a\\\uff085~45\\\uff09\\\u2103\\\uff1b \\\u00a0humidit\u00e9 relative\\\uff1a\\\u226490 pour cent \\\u3002<\/td>\n<\/tr>\n<tr>\n<td>Dimension du trou<\/td>\n<td colspan=\"2\">\\\uff0891\\\u00d791\\\uff09mm\\\u00a0dimension du trou\\\uff1bdimension du panneau\\\uff08100*100\\\uff09mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nUne fois le pH-m\u00e8tre calibr\u00e9, vous pouvez proc\u00e9der \u00e0 la mesure du pH. Commencez par rincer l\u2019\u00e9lectrode avec de l\u2019eau distill\u00e9e puis plongez-la dans la solution dont vous souhaitez mesurer le pH. Laissez la lecture se stabiliser, ce qui peut prendre de quelques secondes \u00e0 une minute, selon les caract\u00e9ristiques de la solution. Assurez-vous que l&#8217;\u00e9lectrode est compl\u00e8tement immerg\u00e9e dans la solution et \u00e9vitez de la remuer ou de la secouer pendant la mesure.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/chimaytech.net\/wp-content\/uploads\/2023\/11\/Spec-pH-ORP8500A-meter-pH-controller-with-RS485.png\" alt=\"alt-5919\" class=\"wp-image-5919\" id=\"i5919\" \/><\/p>\n<p>\nUne fois la lecture stabilis\u00e9e, enregistrez la valeur du pH affich\u00e9e sur l&#8217;appareil de mesure. Si vous mesurez le pH d&#8217;un \u00e9chantillon solide, vous pouvez cr\u00e9er une suspension en m\u00e9langeant l&#8217;\u00e9chantillon avec de l&#8217;eau distill\u00e9e, puis en mesurant le pH de la solution obtenue. N&#8217;oubliez pas de rincer l&#8217;\u00e9lectrode avec de l&#8217;eau distill\u00e9e entre les mesures pour \u00e9viter toute contamination.<\/p>\n<div style=\"width: 640px;\" class=\"wp-video\"><!--[if lt IE 9]><script>document.createElement('video');<\/script><![endif]-->\n<video class=\"wp-video-shortcode\" id=\"video-20097-1\" width=\"640\" height=\"360\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/ROC-8221-Factory-supply-Single-Stage-Double-Channels-RO-Controller.mp4?_=1\" \/><a href=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/ROC-8221-Factory-supply-Single-Stage-Double-Channels-RO-Controller.mp4\">http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/ROC-8221-Factory-supply-Single-Stage-Double-Channels-RO-Controller.mp4<\/a><\/video><\/div>\n<p>Il est essentiel de manipuler le pH-m\u00e8tre avec pr\u00e9caution pour garantir des mesures pr\u00e9cises. \u00c9vitez de toucher l&#8217;\u00e9lectrode avec vos doigts, car les huiles et la salet\u00e9 peuvent affecter les lectures. Rangez correctement le pH-m\u00e8tre lorsqu&#8217;il n&#8217;est pas utilis\u00e9, en suivant les instructions du fabricant. Un entretien r\u00e9gulier, tel que le nettoyage de l&#8217;\u00e9lectrode et le remplacement de l&#8217;\u00e9lectrolyte de r\u00e9f\u00e9rence, contribuera \u00e0 prolonger la dur\u00e9e de vie du pH-m\u00e8tre et \u00e0 maintenir sa pr\u00e9cision.<\/p>\n<p>En conclusion, mesurer le pH \u00e0 l&#8217;aide d&#8217;un pH-m\u00e8tre est un processus simple qui n\u00e9cessite un \u00e9talonnage, une manipulation et un entretien appropri\u00e9s. . En suivant le guide \u00e9tape par \u00e9tape d\u00e9crit dans cet article, vous pouvez obtenir des mesures de pH pr\u00e9cises pour vos exp\u00e9riences ou applications. N&#8217;oubliez pas de calibrer le pH-m\u00e8tre avant chaque utilisation, de le manipuler avec pr\u00e9caution pendant les mesures et de le ranger correctement lorsqu&#8217;il n&#8217;est pas utilis\u00e9. La mesure du pH est une technique fondamentale dans diverses disciplines scientifiques, et ma\u00eetriser l&#8217;utilisation d&#8217;un pH-m\u00e8tre est indispensable pour obtenir des r\u00e9sultats fiables.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/chimaytech.net\/wp-content\/uploads\/2023\/11\/TUR-6101.jpg\" alt=\"alt-5924\" class=\"wp-image-5924\" id=\"i5924\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Proc\u00e9dure op\u00e9ratoire standard pour l&#8217;\u00e9talonnage d&#8217;un pH-m\u00e8tre Un pH-m\u00e8tre est un outil crucial dans de nombreuses applications scientifiques et industrielles, car il permet de mesurer avec pr\u00e9cision l&#8217;acidit\u00e9 ou l&#8217;alcalinit\u00e9 d&#8217;une solution. Pour garantir la fiabilit\u00e9 des mesures de pH, il est indispensable de calibrer r\u00e9guli\u00e8rement le pH-m\u00e8tre. Dans cet article, nous pr\u00e9senterons la proc\u00e9dure&#8230;<\/p>\n","protected":false},"author":1,"featured_media":19687,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"default","_kad_post_title":"default","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[202],"tags":[203228,87669,203501,203661],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"fr","enabled_languages":["en","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"ar":{"title":true,"content":true,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"id":{"title":true,"content":true,"excerpt":false},"hi":{"title":true,"content":true,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/posts\/20097"}],"collection":[{"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/comments?post=20097"}],"version-history":[{"count":16,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/posts\/20097\/revisions"}],"predecessor-version":[{"id":20501,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/posts\/20097\/revisions\/20501"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/media\/19687"}],"wp:attachment":[{"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/media?parent=20097"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/categories?post=20097"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/tags?post=20097"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}