{"id":20025,"date":"2024-06-12T17:05:38","date_gmt":"2024-06-12T09:05:38","guid":{"rendered":"https:\/\/chimaytech.net\/?p=20025"},"modified":"2024-06-13T22:08:49","modified_gmt":"2024-06-13T14:08:49","slug":"oxyguard-dissolved-oxygen-meter-2","status":"publish","type":"post","link":"https:\/\/chimaytech.net\/fr\/oxyguard-dissolved-oxygen-meter-2\/","title":{"rendered":"compteur d&#039;oxyg\u00e8ne dissous oxyguard"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_50 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/chimaytech.net\/fr\/oxyguard-dissolved-oxygen-meter-2\/#Avantages_de_l%E2%80%99utilisation_du_compteur_d%E2%80%99oxygene_dissous_OxyGuard_pour_l%E2%80%99aquaculture\" title=\"Avantages de l&#8217;utilisation du compteur d&#8217;oxyg\u00e8ne dissous OxyGuard pour l&#8217;aquaculture\">Avantages de l&#8217;utilisation du compteur d&#8217;oxyg\u00e8ne dissous OxyGuard pour l&#8217;aquaculture<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/chimaytech.net\/fr\/oxyguard-dissolved-oxygen-meter-2\/#http_shchimaycomwp-contentuploads202311CCT-5300E-Seriesmp4\" title=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CCT-5300E-Series.mp4\">http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CCT-5300E-Series.mp4<\/a><\/li><\/ul><\/nav><\/div>\n<h1 id=\"benefits-of-using-oxyguard-dissolved-oxygen-meter-for-aquaculture-wpaicgheading\"><span class=\"ez-toc-section\" id=\"Avantages_de_l%E2%80%99utilisation_du_compteur_d%E2%80%99oxygene_dissous_OxyGuard_pour_l%E2%80%99aquaculture\"><\/span>Avantages de l&#8217;utilisation du compteur d&#8217;oxyg\u00e8ne dissous OxyGuard pour l&#8217;aquaculture<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>\nComment calibrer et entretenir correctement le compteur d&#8217;oxyg\u00e8ne dissous OxyGuard<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/\\\u4e3b\\\u56fe4.jpg\" alt=\"alt-430\" class=\"wp-image-430\" id=\"i430\" \/><\/p>\n<p>Les compteurs d&#8217;oxyg\u00e8ne dissous OxyGuard sont des outils essentiels pour surveiller les niveaux d&#8217;oxyg\u00e8ne dans l&#8217;eau, que ce soit dans l&#8217;aquaculture, le traitement des eaux us\u00e9es ou d&#8217;autres applications. Pour garantir des lectures pr\u00e9cises, il est crucial de calibrer et d\u2019entretenir correctement votre compteur d\u2019oxyg\u00e8ne dissous OxyGuard. Dans cet article, nous discuterons des \u00e9tapes \u00e0 suivre pour calibrer et entretenir votre compteur afin de garantir des mesures fiables et pr\u00e9cises.<\/p>\n<h1 id=\"how-to-properly-calibrate-and-maintain-oxyguard-dissolved-oxygen-meter-wpaicgheading\"><div style=\"width: 640px;\" class=\"wp-video\"><!--[if lt IE 9]><script>document.createElement('video');<\/script><![endif]-->\n<video class=\"wp-video-shortcode\" id=\"video-20025-1\" width=\"640\" height=\"360\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CCT-5300E-Series.mp4?_=1\" \/><a href=\"http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CCT-5300E-Series.mp4\">http:\/\/shchimay.com\/wp-content\/uploads\/2023\/11\/CCT-5300E-Series.mp4<\/a><\/video><\/div><\/h1>\n<p>\nL&#8217;\u00e9talonnage de votre compteur d&#8217;oxyg\u00e8ne dissous OxyGuard est une \u00e9tape critique pour garantir des lectures pr\u00e9cises. Avant l&#8217;\u00e9talonnage, assurez-vous que le capteur est propre et exempt de tout d\u00e9bris susceptible d&#8217;affecter les lectures. Pour calibrer le compteur, vous aurez besoin de solutions d&#8217;\u00e9talonnage de concentrations d&#8217;oxyg\u00e8ne connues. Il est recommand\u00e9 d&#8217;utiliser au moins deux solutions d&#8217;\u00e9talonnage pour garantir la pr\u00e9cision.<\/p>\n<p>Pour commencer le processus d&#8217;\u00e9talonnage, plongez le capteur dans la premi\u00e8re solution d&#8217;\u00e9talonnage et laissez-le se stabiliser. Suivez les instructions fournies par le fabricant pour r\u00e9gler le compteur afin qu&#8217;il corresponde \u00e0 la concentration d&#8217;oxyg\u00e8ne connue de la solution d&#8217;\u00e9talonnage. R\u00e9p\u00e9tez ce processus avec la deuxi\u00e8me solution d&#8217;\u00e9talonnage pour garantir la pr\u00e9cision sur une plage de concentrations d&#8217;oxyg\u00e8ne.<\/p>\n<p>Mod\u00e8leContr\u00f4leur de conductivit\u00e9 en ligne EC-1800<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Plage<\/td>\n<td>0-2000\/4000uS\/cm 0-20\/200mS\/cm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">0-1000\/2000PPM<\/td>\n<td>Pr\u00e9cision<\/td>\n<\/tr>\n<tr>\n<td>1,5 pour cent, 2 pour cent, 3 pour cent (FS)<\/td>\n<\/tr>\n<tr>\n<td>Temp. Comp.<\/td>\n<td>Compensation automatique de temp\u00e9rature bas\u00e9e sur 25\\\u2103<\/td>\n<\/tr>\n<tr>\n<td>Op\u00e9ra. Temp.<\/td>\n<td>Normal 0\\\uff5e50\\\u2103; Haute temp\u00e9rature 0\\\uff5e120\\\u2103<\/td>\n<\/tr>\n<tr>\n<td>Capteur<\/td>\n<td>C=0,1\/1,0\/10,0 cm<\/td>\n<\/tr>\n<tr>\n<td>Affichage<\/td>\n<td>\u00c9cran LCD 128*64<sup>-1<\/sup><\/td>\n<\/tr>\n<tr>\n<td>Communication<\/td>\n<td>Sortie 4-20mA\/2-10V\/1-5V\/RS485<\/td>\n<\/tr>\n<tr>\n<td>Sortie<\/td>\n<td>Contr\u00f4le de relais double limite haute\/basse<\/td>\n<\/tr>\n<tr>\n<td>Puissance<\/td>\n<td>AC 220V\\\u00b110 pour cent 50\/60Hz ou AC 110V\\\u00b110 pour cent 50\/60Hz ou DC24V\/0.5A<\/td>\n<\/tr>\n<tr>\n<td>Environnement de travail<\/td>\n<td>Temp\u00e9rature ambiante\u00a0:0\\\uff5e50\\\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Humidit\u00e9 relative\\\u226485 pour cent <\/td>\n<td>Dimensions<\/td>\n<\/tr>\n<tr>\n<td>96\\\u00d796\\\u00d7100mm(H\\\u00d7W\\\u00d7L)<\/td>\n<\/tr>\n<tr>\n<td>Taille du trou<\/td>\n<td>92\\\u00d792mm(H\\\u00d7W)<\/td>\n<\/tr>\n<tr>\n<td>Mode Installation<\/td>\n<td>Int\u00e9gr\u00e9<\/td>\n<\/tr>\n<tr>\n<td>Apr\u00e8s avoir calibr\u00e9 votre compteur d&#8217;oxyg\u00e8ne dissous OxyGuard, il est essentiel d&#8217;effectuer un entretien r\u00e9gulier pour le maintenir dans un \u00e9tat de fonctionnement optimal. Un aspect crucial de la maintenance consiste \u00e0 garder le capteur propre. Au fil du temps, des bio-encrassements et des d\u00e9bris peuvent s&#8217;accumuler sur le capteur, affectant sa pr\u00e9cision. Inspectez r\u00e9guli\u00e8rement le capteur et nettoyez-le si n\u00e9cessaire \u00e0 l&#8217;aide d&#8217;une brosse douce ou d&#8217;un chiffon.<\/td>\n<td>Mod\u00e8le de produit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nMFC-8800<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Port de communication<\/td>\n<td colspan=\"2\">Le port RS485 du protocole Modbus RTU du canal esclave de liaison montante est connect\u00e9 au DTU et au DCS<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Le port RS485 du canal ma\u00eetre de liaison descendante du protocole Modbus RTU est connect\u00e9 au terminal d&#8217;acquisition de donn\u00e9es<\/td>\n<td colspan=\"2\">4~20mA\\\u00a0sortie<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Type \u00e0 deux fils \u00e0 1 canal \\\u00a0R\u00e9sistance de boucle maximale 400\\\u03a9<\/td>\n<\/tr>\n<tr>\n<td>4~20mA\\\u00a0Entr\u00e9e<\/td>\n<td colspan=\"2\">\\\u00a02 canal canal type \u00e0 deux fils\\\uff08\\\u00a0alimentation d&#8217;initiative\\\uff09<\/td>\n<\/tr>\n<tr>\n<td>DI\\\u00a0Entr\u00e9e<\/td>\n<td colspan=\"2\">\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\\u00a0\\ \u00a02canaux Commutateur logique d&#8217;isolation photo\u00e9lectrique<\/td>\n<\/tr>\n<tr>\n<td>Sortie DO<\/td>\n<td colspan=\"2\">Relais 3\\\u00a0canaux<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">1\\\u00a0SPDT \\\u00a0AC220V\\\uff1b 3A(MAX)<\/td>\n<td>\\\uff08uniquement pour le signal d&#8217;entra\u00eenement\\\uff09<\/td>\n<td>2\\\u00a0SPST \\\u00a0AC220V\\\uff1b 3A(MAX)<\/td>\n<\/tr>\n<tr>\n<td>1 canal \\\u00a0Interrupteur photo\u00e9lectrique \\\u00a0\\\u00a0<\/td>\n<td>Impulsion\/fr\u00e9quence proportionnelle<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\\\u00a0Capacit\u00e9 de charge\\\uff1a100mA\/DC30V<\/td>\n<td>\\\u00a0Acquisition de donn\u00e9es<\/td>\n<\/tr>\n<tr>\n<td>Collecte d&#8217;acquisition de donn\u00e9es\\\uff0cavec 3\\\u00a0canaux DC24V alimentation du capteur \\\u00a0<\/td>\n<\/tr>\n<tr>\n<td>Mode d&#8217;affichage<\/td>\n<td colspan=\"2\">\u00c9cran tactile LCD color\u00e9 3,5\\\uff08ou 4\\\u201d\uff09<\/td>\n<\/tr>\n<tr>\n<td>Alimentation<\/td>\n<td colspan=\"2\">Large plage de puissance \\\uff1a\\\uff0812-24\\\uff09V<\/td>\n<\/tr>\n<tr>\n<td>Consommation<\/td>\n<td colspan=\"2\">Exigences environnementales<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de l&#8217;environnement\\\uff1a\\\uff085~45\\\uff09\\\u2103\\\uff1b \\\u00a0humidit\u00e9 relative\\\uff1a\\\u226490 pour cent \\\u3002<\/td>\n<td colspan=\"2\"><5W<\/td>\n<\/tr>\n<tr>\n<td>Dimension du trou<\/td>\n<td colspan=\"2\">\\\uff0891\\\u00d791\\\uff09mm\\\u00a0dimension du trou\\\uff1bdimension du panneau\\\uff08100*100\\\uff09mm<\/td>\n<\/tr>\n<tr>\n<td>En plus de garder le capteur propre, il est \u00e9galement important de v\u00e9rifier l&#8217;\u00e9tat de la membrane du capteur. La membrane est un composant essentiel du capteur qui permet \u00e0 l&#8217;oxyg\u00e8ne de se diffuser dans le capteur pour la mesure. Si la membrane est endommag\u00e9e ou us\u00e9e, cela peut affecter la pr\u00e9cision des lectures. Inspectez r\u00e9guli\u00e8rement la membrane et remplacez-la si n\u00e9cessaire pour garantir des mesures pr\u00e9cises.<\/td>\n<td colspan=\"2\">En conclusion, l\u2019\u00e9talonnage et l\u2019entretien de votre compteur d\u2019oxyg\u00e8ne dissous OxyGuard sont cruciaux pour des mesures pr\u00e9cises et fiables. En suivant les \u00e9tapes d\u00e9crites dans cet article, vous pouvez vous assurer que votre compteur est dans un \u00e9tat de fonctionnement optimal et qu&#8217;il fournit des lectures pr\u00e9cises des niveaux d&#8217;oxyg\u00e8ne dans l&#8217;eau. Un \u00e9talonnage et un entretien r\u00e9guliers am\u00e9lioreront non seulement les performances de votre compteur, mais prolongeront \u00e9galement sa dur\u00e9e de vie, vous permettant ainsi d&#8217;\u00e9conomiser du temps et de l&#8217;argent \u00e0 long terme.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>\nIn addition to keeping the sensor clean, it is also important to check the condition of the sensor membrane. The membrane is a critical component of the sensor that allows oxygen to diffuse into the sensor for measurement. If the membrane becomes damaged or worn, it can affect the accuracy of the readings. Inspect the membrane regularly and replace it as needed to ensure accurate measurements.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/chimaytech.net\/wp-content\/uploads\/2024\/06\/PH-ORP-6900-PH-orp-controller-1.jpg\" alt=\"alt-4318\" class=\"wp-image-4318\" id=\"i4318\" \/><\/p>\n<p>Another important aspect of maintaining your OxyGuard <a href=\"\/tag\/Dissolved-Oxygen-Meter\" target=\"_blank\"><strong><a href=\"\/tag\/dissolved-oxygen-meter\/\" target=\"_blank\"><strong>dissolved oxygen meter<\/strong><\/a><\/strong><\/a> is ensuring that the electronics are functioning correctly. Check the battery levels regularly and replace them as needed to prevent any interruptions in monitoring. Additionally, inspect the cables and connections for any signs of wear or damage that could affect the performance of the meter.<\/p>\n<p>Regularly calibrating and maintaining your OxyGuard dissolved oxygen meter is essential for ensuring accurate and reliable measurements. By following the steps outlined in this article, you can keep your meter in optimal working condition and ensure that you are getting accurate readings of oxygen levels in water. Proper calibration and maintenance will not only improve the performance of your meter but also extend its lifespan, saving you time and money in the long run.<\/p>\n<div class=\"entry-content-asset videofit\"><iframe loading=\"lazy\" title=\"conductivity meter working principle\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/huEnM2S4aYE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>In conclusion, calibrating and maintaining your OxyGuard dissolved oxygen meter is crucial for accurate and reliable measurements. By following the steps outlined in this article, you can ensure that your meter is in optimal working condition and providing accurate readings of oxygen levels in water. Regular calibration and maintenance will not only improve the performance of your meter but also extend its lifespan, saving you time and money in the long run.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Avantages de l&#8217;utilisation du compteur d&#8217;oxyg\u00e8ne dissous OxyGuard pour l&#8217;aquaculture Comment calibrer et entretenir correctement le compteur d&#8217;oxyg\u00e8ne dissous OxyGuard Les compteurs d&#8217;oxyg\u00e8ne dissous OxyGuard sont des outils essentiels pour surveiller les niveaux d&#8217;oxyg\u00e8ne dans l&#8217;eau, que ce soit dans l&#8217;aquaculture, le traitement des eaux us\u00e9es ou d&#8217;autres applications. Pour garantir des lectures pr\u00e9cises, il&#8230;<\/p>\n","protected":false},"author":1,"featured_media":20029,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"default","_kad_post_title":"default","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[202],"tags":[87075,203228,87081,87367,87617],"translation":{"provider":"WPGlobus","version":"2.12.0","language":"fr","enabled_languages":["en","es","de","fr","ru","pt","ar","ja","ko","it","id","hi","th","vi","tr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"ar":{"title":true,"content":true,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"id":{"title":true,"content":true,"excerpt":false},"hi":{"title":true,"content":true,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/posts\/20025"}],"collection":[{"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/comments?post=20025"}],"version-history":[{"count":18,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/posts\/20025\/revisions"}],"predecessor-version":[{"id":20351,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/posts\/20025\/revisions\/20351"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/media\/20029"}],"wp:attachment":[{"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/media?parent=20025"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/categories?post=20025"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chimaytech.net\/fr\/wp-json\/wp\/v2\/tags?post=20025"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}