Troubleshooting Common Issues with Autotrol 268 460i Manual

The Autotrol 268 460i manual is a valuable resource for anyone who owns or operates this particular water softener system. However, like any piece of equipment, there may be times when you encounter issues that require troubleshooting. In this article, we will discuss some common problems that users may face with the Autotrol 268 460i manual and provide solutions to help resolve them.

One of the most common issues that users may encounter with the Autotrol 268 460i manual is a lack of water softening. This can be caused by a number of factors, including a malfunctioning control valve, a clogged resin bed, or incorrect settings on the control panel. To troubleshoot this issue, start by checking the control valve to ensure that it is functioning properly. If the valve is not opening and closing as it should, it may need to be replaced.

Another common issue that users may face with the Autotrol 268 460i manual is a salt bridge. A salt bridge occurs when a hard crust forms in the brine tank, preventing the salt from dissolving properly and inhibiting the regeneration process. To resolve this issue, carefully break up the salt bridge using a broom handle or other long, sturdy object. Once the salt bridge has been broken up, add additional salt to the brine tank to ensure that the water softener system can regenerate properly.

Users may also encounter issues with the Autotrol 268 460i manual if the system is not regenerating properly. This can be caused by a number of factors, including a malfunctioning timer, a clogged injector, or insufficient water pressure. To troubleshoot this issue, start by checking the timer to ensure that it is set correctly. If the timer is not functioning properly, it may need to be replaced. Additionally, check the injector for any clogs or blockages that may be preventing the system from regenerating properly. Finally, ensure that the water pressure is sufficient to allow the system to regenerate effectively.

In some cases, users may find that the Autotrol 268 460i manual is displaying error codes that they are unfamiliar with. These error codes can indicate a variety of issues, including low salt levels, a malfunctioning sensor, or a problem with the control panel. To troubleshoot these error codes, refer to the troubleshooting section of the manual for guidance on how to resolve the issue. If you are unable to resolve the issue on your own, contact a professional water softener technician for assistance.

Overall, the Autotrol 268 460i manual is a valuable resource for troubleshooting common issues with this water softener system. By following the troubleshooting tips outlined in this article, users can effectively resolve issues such as lack of water softening, salt bridges, improper regeneration, and error codes. If you continue to experience issues with your Autotrol 268 460i manual, do not hesitate to seek professional assistance to ensure that your water softener system is functioning properly.

Step-by-Step Guide to Programming Autotrol 268 460i Manual

The Autotrol 268 460i manual is a valuable resource for anyone looking to program their autotrol water softener system. This manual provides detailed instructions on how to set up and customize the settings on your water softener to meet your specific needs. In this article, we will provide a step-by-step guide to programming the Autotrol 268 460i manual.

alt-1010

To begin programming your Autotrol water softener system, you will first need to locate the control panel on the unit. The control panel is typically located on the front of the unit and is where you will input all of your programming settings. Once you have located the control panel, you can begin the programming process.

The first step in programming your Autotrol water softener system is to set the current time and date. This is important for ensuring that your system operates efficiently and accurately. To set the time and date, simply follow the instructions in the manual for entering the correct information.

Next, you will need to set the regeneration time for your water softener system. The regeneration time is the time of day when the system will automatically regenerate and clean itself. This is typically done late at night when water usage is at its lowest. To set the regeneration time, refer to the manual for instructions on how to input the desired time.

After setting the regeneration time, you will need to program the hardness level of your water. The hardness level is a measure of the mineral content in your water and will determine how often your system regenerates. To program the hardness level, follow the instructions in the manual for entering the correct value based on your water test results.

Once you have programmed the hardness level, you can then set the regeneration frequency for your water softener system. The regeneration frequency is how often the system will regenerate based on the hardness level of your water. To set the regeneration frequency, refer to the manual for instructions on how to input the desired frequency.

After programming the regeneration frequency, you can customize any additional settings on your Autotrol water softener system. This may include setting the salt dosage, adjusting the backwash time, or enabling any additional features that your system may have. Refer to the manual for specific instructions on how to customize these settings.

Once you have completed programming your Autotrol water softener system, be sure to save your settings to ensure they are retained in the system’s memory. This will prevent you from having to reprogram the system in the event of a power outage or system reset.

Model AFC2-LCD AFC2-LED
Working Position Filter->Back wash 1->Back wash 2-> Fast rinse -> Filter 
Regeneration mode Automatic  Automatic 
Time by day :0-99days Time by day :0-99days
Time by hours:0-99 hours Time by hours:0-99 hours
In (inlet of valve) 1/2”F 1/2”F
I1(inlet of first filter) 1/2”F 1/2”F
I2(inlet of second filter) 1/2”F 1/2”F
Drain 1/2”M 1/2”M
D1( Drain of first filter) 1/2”M 1/2”M
D2(Drain of second filter) 1/2”M 1/2”M
Water capacity  2m3/h 2m3/h
Working pressure 0.15-0.6Mpa
Power Supply  AC100-240V/ 50-60Hz      /    DC12V-1.5A

In conclusion, programming the Autotrol 268 460i manual is a straightforward process that can be easily completed by following the step-by-step instructions provided in the manual. By programming your water softener system correctly, you can ensure that it operates efficiently and effectively to provide you with high-quality softened water for your home.